Applies to: ACSX6 (ACSX)
What does Scania ACSX fault code 522 mean?
Communication fault in the articulation control system CAN sub data bus.
What causes Scania DTC 522?
- Fault in the ACSX control unit connection to the sub data bus. - Fault in the articulation control system sub data bus. - Wake-up signal to the ACSX control unit is short-circuited to voltage supply.
What are the symptoms?
Articulation damping functionality is limited.
How to fix Scania ACSX fault code 522?
- Check the ACSX control unit connection to the sub data bus.
- Check the articulation control system sub data bus:
- Disconnect the battery and measure the resistance between CAN high and CAN low on the ACSX control unit.
- Resistance should be close to 60 ohm.
- Disconnect the battery and measure the resistance between CAN high on the ACSX control unit and CAN high on the ACS control unit.
- Resistance should be close to 0 ohm.
- Disconnect the battery and measure the resistance between CAN low on the ACSX control unit and CAN low on the ACS control unit.
- Resistance should be close to 0 ohm.
- Check the wake-up signal to the ACSX control unit (15 voltage).
This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.
Code 522 in other Scania systems
- 522hex 020A Articulation control system sub data bus
- 522hex 020A Communication with the engine management system (EMS)
- 522hex 020A Time-out in TMS CAN node
- 522hex 020A CAN communication on the control unit sub data bus 1
- 522hex 020A Communication, brown CAN bus (CAN1)
- 522hex 020A #Not implemented. Electrical error on CAN bus 2
- 522hex 020A TCC control unit, electrical fault in brown CAN bus