Scania APS DTC 3014666 Compressor

APS Air Processing System · Scania · 2 variants

Code 3014666 (decimal). Some diagnostic tools show it in hexadecimal as 2E000A.

In short

Incorrect configuration.

Variant 1

Applies to: APS2

What does Scania APS fault code 3014666 mean?

Incorrect configuration.

What causes Scania DTC 3014666?

The fault code is generated when the pressure increases at a faster rate than the system is configured for and this may have occurred because: - The system configuration does not correspond to the compressor.

What are the symptoms?

When the fault is active the calculations for the amount of air that passes the desiccant container are incorrect, which can result in the pneumatic system filling with water.

How to fix Scania APS fault code 3014666?

Carry out spare parts programming to reset the configuration of the system.

Variant 2

Applies to: APS2

Detection

Incorrect configuration.

Possible cause

The fault code is generated when the pressure increases at a faster rate than the system is configured for and this may have occurred because: - The system configuration does not correspond to the compressor.

System reaction

When the fault is active the calculations for the amount of air that passes the desiccant container are incorrect, which can result in the pneumatic system filling with water.

How to fix

Carry out spare parts programming to reset the configuration of the system.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.