Scania CCU DTC 41022 Actuator for air distribution between panel and floor, electrical fault

CCU CCU control unit · Scania

Code 41022 (decimal). Some diagnostic tools show it in hexadecimal as A03E.

In short

Electrical fault in the air distribution actuator between panel and floor.

Applies to: CCU1

What does Scania CCU fault code 41022 mean?

Electrical fault in the air distribution actuator between panel and floor.

What causes Scania DTC 41022?

- Fault in the cable harness between the control unit and the actuator for air distribution between panel and floor. - Fault in the actuator for air distribution between panel and floor.

What are the symptoms?

- The actuator cannot regulate the air distribution between the panel and floor. - Components on the LIN bus are connected to the control unit in series via harness-to-harness connectors. A fault in components previously connected to the cable harness can therefore affect the functionality of components connected later.

How to fix Scania CCU fault code 41022?

  1. Check the cable harness between the control unit and the actuator for air distribution between panel and floor.
  2. If no fault is found, replace the actuator.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 41022 in other Scania systems

Compare code 41022 in every system →