Scania EMO DTC 4111 NOx sensor T115 downstream of the SCR catalytic converter measures too low a value.

EMO EMO control unit · Scania

Code 4111 (decimal). Some diagnostic tools show it in hexadecimal as 100F.

In short

NOx sensor T115 downstream of the catalytic converter has not started within a set time.

Applies to: EMO2 (EMS)

What does Scania EMO fault code 4111 mean?

NOx sensor T115 downstream of the catalytic converter has not started within a set time.

What causes Scania DTC 4111?

Fault in the NOx sensor.

How does the system react?

The fault affects the engine's nitrous oxide emissions. Depending on the emission class, this may result in torque reduction, speed limitation and a warning indication.

How to fix Scania EMO fault code 4111?

  1. Applies only to vehicles with Euro 4 or Euro 5: Renew NOx sensor T115.
  2. The fault code will become inactive after the NOx sensor start-up phase.
  3. On vehicles with SCR system: Run Function test of exhaust gas aftertreatment SCR, select section Checking the NOx sensors.
  4. Proceed as follows to extinguish the emissions warning lamp.
  5. Turn the starter key to the locking position.
  6. Wait until the button for the hazard warning signal has been extinguished.
  7. Turn the starter key to the drive position.
  8. Check that the fault code has been deactivated.
  9. Turn the starter key to the drive position and then back to the locking position 3 times.
  10. Wait until the button for the hazard warning signal has extinguished between each turn.
  11. The emissions warning lamp should then be extinguished.
  12. Clear the fault code.
  13. Applies only to vehicles with Euro 6 and Scania Engines with variable geometry turbocharger and EGR: Renew NOx sensor T115.
  14. The fault code will become inactive after the NOx sensor start-up phase.
  15. Run Function test of exhaust gas aftertreatment SCR, select section Checking the NOx sensors.
  16. Clear the fault code.
  17. Applies only to Scania Engines without variable geometry turbocharger and EGR and 16-litre engines without exhaust brake: Renew NOx sensor T115.
  18. The fault code will become inactive after the NOx sensor start-up phase.
  19. Start the engine and run the engine under load.
  20. Check the amount of dosed reductant via Reductant doser V117.
  21. When the amount is larger than 0: check via NOx sensor downstream of the catalytic converter T115 that the NOx sensor starts within 15 minutes.
  22. Clear the fault code.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 4111 in other Scania systems

Compare code 4111 in every system →