Scania DCS DTC 1048598 Background lighting in the driver’s door, short circuit

DCS DCS control unit · Scania · 2 variants

Code 1048598 (decimal). Some diagnostic tools show it in hexadecimal as 100016.

In short

The background lighting in the driver’s door L170 is short-circuited to ground or supply voltage.

Variant 1

Applies to: DCS1 (DCS)

What does Scania DCS fault code 1048598 mean?

The background lighting in the driver’s door L170 is short-circuited to ground or supply voltage.

What causes Scania DTC 1048598?

- Fault in harness-to-component connectors or cable harness of the background lighting in the driver's door L170. - Fault in the background lighting in the driver’s door L170.

What are the symptoms?

The background lighting is not working.

How to fix Scania DCS fault code 1048598?

  1. Disconnect the background lighting in the driver’s door L170.
  2. Note whether a new fault code for an open circuit is set.
  3. If this is the case, the fault is probably in the component.
  4. Measure on the pins in the nearest harness-to-component connector leading to control unit pins A4 (voltage) and A9 (ground).
  5. Disconnect the harness-to-component connector on the control unit.
  6. Measure for short circuits throughout the cable harness.
  7. If there are several harness-to-component connectors between the component and the control unit, also measure these to locate the fault.
  8. If the fault is not in the cable harness or the component, it is probably an internal fault in the control unit.

Variant 2

Applies to: DCS1

Detection

The background lighting in the driver’s door L170 is short-circuited to ground or supply voltage.

Possible cause

- Fault in harness-to-component connectors or cable harness of the background lighting in the driver's door L170. - Fault in the background lighting in the driver’s door L170.

System reaction

The background lighting is not working.

How to fix

  1. Disconnect the background lighting in the driver’s door L170.
  2. Note whether a new fault code for an open circuit has been generated.
  3. If this is the case, the fault is probably in the component.
  4. Measure on the pins in the nearest harness-to-component connector leading to control unit pins A4 (voltage) and A9 (earth).
  5. Disconnect the harness-to-component connector on the control unit.
  6. Measure for short circuits throughout the cable harness.
  7. If there are several harness-to-component connectors between the component and the control unit, then also measure these to locate the fault.
  8. If the fault is not in the cable harness or the component, it is probably an internal fault in the control unit.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.