Variant 1
Applies to: ELC3
What does Scania ELC fault code 822 mean?
The voltage on the input from the control box has been too low.
What causes Scania DTC 822?
This fault code is generated if the control box and/or cable harness has been shorted to ground.
How does the system react?
If the fault occurs there will be no standby function and level control using the control box. The yellow warning symbol is on when the fault is active. Note: On vehicles with blackout lighting (BOL) the fault code can be ignored. The fault code is activated on these vehicles since supply and ground to the operation unit are interrupted when the blackout lighting function is used.
How to fix Scania ELC fault code 822?
Check the cable harness for damage or forbidden connections and make sure the control box is intact.
Variant 2
Applies to: ELC3 (ELC3Rear)
Detection
The voltage on the input from the control box has been too low.
Possible cause
This fault code is generated if the control box and/or cable harness has been shorted to ground.
System reaction
If the fault occurs there will be no standby function and level control using the control box. The yellow warning symbol is on when the fault is active. Note: On vehicles with blackout lighting (BOL) the fault code can be ignored. The fault code is activated on these vehicles since supply and ground to the operation unit are interrupted when the blackout lighting function is used.
How to fix
Check the cable harness for damage or forbidden connections and make sure the control box is intact.
This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.
Code 822 in other Scania systems
- 822hex 0336 Changed polarity on the 24 V side of the direct current converter E84 (DCC)
- 822hex 0336 Pressure sensor for rear axle, left-hand side
- 822hex 0336 Switch module
- 822hex 0336 Changed polarity on the 24 V side of the direct current converter (DCC)
- 822hex 0336 #Not implemented. Secondary passenger area condenser fan defectives