Scania EMD DTC 1682 Cooling fan

EMD EMD control unit · Scania

Code 1682 (decimal). Some diagnostic tools show it in hexadecimal as 0692.

In short

The voltage in the circuit has been outside the permitted range.

Applies to: EMD0EMD1

What does Scania EMD fault code 1682 mean?

The voltage in the circuit has been outside the permitted range.

What causes Scania DTC 1682?

- Fault in the cooling fan harness-to-harness connectors or cable harness. - Fault in the cooling fan.

What are the symptoms?

If the cooling fan is hydraulically controlled (V119), it cannot be switched off. If the cooling fan is electrically controlled (T123), it will not work at all.

How to fix Scania EMD fault code 1682?

Check the cooling fan along with the circuit components, harness-to-harness connectors and electrical cables.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 1682 in other Scania systems

Compare code 1682 in every system →