Variant 1
Applies to: EMS10
What does Scania EMS fault code 4136 mean?
The measured concentration of the reductant is too low.
What causes Scania DTC 4136?
Poor quality of the reducing agent (too low concentration of reductant). Faulty urea quality sensor [T116].
How to fix Scania EMS fault code 4136?
- Ensure that the reductant tank contains reducing agent of the appropriate quality (31-34% urea concentration).
- Check the urea quality sensor.
- Verify that the urea concentration measured by the urea quality sensor agrees with the concentration measured with refractometer.
Variant 2
Applies to: EMS S8
Detection
The concentration of reductant is too low.
Possible cause
The fault may be due to low quality reductant.
System reaction
The fault affects the engine's nitrous oxide emissions.
How to fix
- Rectify any other fault codes relevant to the engine and the exhaust gas aftertreatment management system.
- Using the reductant quality sensor T116, check that the reductant tank contains reductant of the right quality with a concentration of 31-34%.
- If the quality is too low, the driver should contact the reductant supplier.
- Switch to a reductant of the correct quality.
- Refer to Workshop Manual > 03-26 Exhaust gas aftertreatment > Exhaust gas aftertreatment Euro 6 and Post NLT > Checking the reductant quality.
- Verification Run the wizard Exhaust gas aftertreatment, function test SCR to verify that the fault has been rectified.
This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.
Code 4136 in other Scania systems
- 4136hex 001028 Blind spot warning lamp 1 on the left-hand side, short circuit to earth
- 4136hex 1028 Reductant quality too low
- 4136hex 1028 Reductant quality too low
- 4136hex 1028 Reductant quality too low
- 4136hex 001028 Temperature sensor T516, short circuit to supply voltage or open circuit
- 4136hex 1028 Remote control 1