Scania EMU DTC 4096 Temperature sensor T273, battery circuit 1, short circuit to earth

EMU EMU control unit · Scania

Code 4096 (decimal). Some diagnostic tools show it in hexadecimal as 001000.

In short

The control unit gives an implausibly low voltage on the input signal, which indicates a short circuit to earth.

Applies to: EMU1 (ECS)

What does Scania EMU fault code 4096 mean?

The control unit gives an implausibly low voltage on the input signal, which indicates a short circuit to earth.

What causes Scania DTC 4096?

- Fault in cable harness or connector. - Fault in the temperature sensor. - Fault in control unit E159.

How does the system react?

- A yellow warning indication is displayed. - Heater B H40 is switched off. - Valve V238 will not open.

What are the symptoms?

- Higher energy consumption. - Reduced range. - Can lead to performance issues in cold climates. - The fans are running at an unnecessary frequency.

How to fix Scania EMU fault code 4096?

  1. Check the temperature sensor, connector and cable harness.
  2. Change the temperature sensor, contactor or wiring harness to the sensor.
  3. Replace control unit E159.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 4096 in other Scania systems

Compare code 4096 in every system →