Applies to: EMU1 (ECS)
What does Scania EMU fault code 4097 mean?
The control unit states an implausibly high voltage, which indicates an open circuit.
What causes Scania DTC 4097?
- Fault in cable harness or connector. - Fault in the temperature sensor. - Fault in control unit E159.
How does the system react?
- A yellow warning indication is displayed. - Heater B H40 is switched off. - Valve V238 will not open. - The system cools more than usual so as not to risk overheating in the batteries. The fan will run a lot and this can affect the vehicle range.
What are the symptoms?
Can lead to performance issues in cold climates.
How to fix Scania EMU fault code 4097?
- Check the temperature sensor, connectors and cable harness.
- Replace the temperature sensor, cable harness or harness-to-component connector to the sensor.
- Replace control unit E159.
This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.
Code 4097 in other Scania systems
- 4097hex 1001 Exhaust gas aftertreatment (SCR), interrupted post circulation of reductant
- 4097hex 001001 Voltage supply to BMU control unit
- 4097hex 1001 Exhaust gas aftertreatment (SCR), interrupted post circulation of reductant
- 4097hex 1001 Engine speed
- 4097hex 1001 High pressure solenoid valve
- 4097hex 1001 General function indication, warning
- 4097hex 1001 MGU control unit, incorrect torque
- 4097hex 001001 Friction torque of ICE erroneous signal