Variant 1
Applies to: SC1 (TCO)
What does Scania SC fault code 313 mean?
Faulty communication between internal components in the tachograph. The fault is detected during the diagnostic self-test that the tachograph performs on start-up.
What causes Scania DTC 313?
Internal fault in the tachograph.
How to fix Scania SC fault code 313?
- Try turning the voltage on and off.
- If this does not help and the fault code remains active, the tachograph must be renewed.
Variant 2: Tachograph
Applies to: SC2 (TCO)
Detection
Incorrect or unreliable data. The codes 1, 2, 3 and 4 are shown in the tachograph display for this fault code.
Possible cause
Internal fault in the tachograph.
System reaction
The codes 1, 2, 3 and 4 are shown in the tachograph display for this fault code.
How to fix
- Clear the fault code.
- Cut off the power to the tachograph.
- Restore power to the tachograph.
- If the fault code recurs, renew the tachograph.
Variant 3: Internal fault
Applies to: SC3 (TCO)
Detection
Faulty communication between internal components in the tachograph. The fault is detected during the diagnostic self-test that the tachograph performs on start-up.
Possible cause
Internal fault in the tachograph.
How to fix
- Try turning the voltage on and off.
- If this does not help and the fault code remains active, the tachograph must be renewed.
Variant 4: Tachograph
Applies to: SC4 (TCO)
Detection
Incorrect or unreliable data, the system has detected an incorrect shutdown.
Possible cause
- Internal fault in the tachograph. - The system has restarted due to a loss of power.
System reaction
The event is stored in the tachograph and in the digital tachograph card. A fault message is displayed.
How to fix
- Check the voltage supply to the tachograph.
- Clear the fault code.
- Cut off the power to the tachograph.
- Restore power to the tachograph.
- If the fault code recurs, renew the tachograph.
Variant 5: Internal fault
Applies to: SC5 (TCO)
Detection
Faulty communication between internal components in the tachograph. The fault is detected during the diagnostic self-test that the tachograph performs on start-up.
Possible cause
Internal fault in the tachograph.
How to fix
Renew the tachograph.
Variant 6: Tachograph
Applies to: SC6 (TCO)
Detection
Incorrect or unreliable data, the system has detected an incorrect shutdown.
Possible cause
- Internal fault in the tachograph. - The system has restarted due to a loss of power.
System reaction
The event is stored in the tachograph and in the digital tachograph card. An error message is displayed.
How to fix
- Check the voltage supply to the tachograph.
- Clear the fault code.
- Cut the power to the tachograph.
- Restore power to the tachograph.
- If the fault code recurs, renew the tachograph.