Scania APS DTC 562 Measuring voltage

APS Air Processing System · Scania

Code 562 (decimal). Some diagnostic tools show it in hexadecimal as 0232.

In short

Internal power supply malfunction.

Applies to: APS1

What does Scania APS fault code 562 mean?

Internal power supply malfunction.

What causes Scania DTC 562?

Internal fault in the control unit.

How does the system react?

The system can no longer check incoming voltages. As a result, fault codes indicating that the voltage is too high or too low can no longer be generated.

How to fix Scania APS fault code 562?

  1. Clear the fault code.
  2. Turn off the power with the starter key.
  3. Wait for 60 seconds.
  4. Switch on the voltage with the starter key.
  5. If the fault code it still active, renew the control unit.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.