Scania CUV DTC 562 Horn

CUV Visibility system · Scania · 2 variants

Code 562 (decimal). Some diagnostic tools show it in hexadecimal as 0232.

In short

Current consumption on the control unit output has exceeded 5 A for one second.

Variant 1

Applies to: CUV2

What does Scania CUV fault code 562 mean?

Current consumption on the control unit output has exceeded 5 A for one second.

What causes Scania DTC 562?

Short circuit or overload on the horn output signal.

How does the system react?

Horn is inoperative. Every time the function is activated, the current consumption on the control unit output is checked. If the current consumption is too high, the output is switched off and a fault code is registered.

How to fix Scania CUV fault code 562?

Check whether the horn and the cable harness are short circuited to ground.

Variant 2

Applies to: CUV3 (VIS)

Detection

Current consumption on the control unit output has exceeded 5 A for one second.

Possible cause

Short circuit or overload on the horn output signal.

System reaction

Every time the function is activated, the current consumption on the control unit output is checked. If the current consumption is too high, the output is switched off and a fault code is registered.

Symptoms

Horn is inoperative.

How to fix

Check whether the horn and the cable harness are short circuited to ground.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 562 in other Scania systems