Variant 1
Applies to: CUV2
What does Scania CUV fault code 562 mean?
Current consumption on the control unit output has exceeded 5 A for one second.
What causes Scania DTC 562?
Short circuit or overload on the horn output signal.
How does the system react?
Horn is inoperative. Every time the function is activated, the current consumption on the control unit output is checked. If the current consumption is too high, the output is switched off and a fault code is registered.
How to fix Scania CUV fault code 562?
Check whether the horn and the cable harness are short circuited to ground.
Variant 2
Applies to: CUV3 (VIS)
Detection
Current consumption on the control unit output has exceeded 5 A for one second.
Possible cause
Short circuit or overload on the horn output signal.
System reaction
Every time the function is activated, the current consumption on the control unit output is checked. If the current consumption is too high, the output is switched off and a fault code is registered.
Symptoms
Horn is inoperative.
How to fix
Check whether the horn and the cable harness are short circuited to ground.
This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.
Code 562 in other Scania systems
- 562hex 0232 CAN communication with the instrument cluster (ICL)
- 562hex 0232 CAN communication with the instrument cluster (ICL)
- 562hex 0232 Measuring voltage
- 562hex 0232 Timeout in IBU CAN node
- 562hex 0232 Short circuit, C628-16
- 562hex 0232 Communication with the BCS control unit
- 562hex 0232 No CAN message
- 562hex 0232 No CAN message
- 562hex 0232 MBS expansion unit C, fault in CAN communication