Scania APS DTC 770 Control unit

APS Air Processing System · Scania

Code 770 (decimal). Some diagnostic tools show it in hexadecimal as 0302.

In short

The internal supply voltage has been outside the permitted range.

Applies to: APS1

What does Scania APS fault code 770 mean?

The internal supply voltage has been outside the permitted range.

What causes Scania DTC 770?

Internal fault in the control unit.

How does the system react?

The system changes to working at reduced pressure.

How to fix Scania APS fault code 770?

  1. Clear the fault code.
  2. Turn off the power with the starter key.
  3. Wait for 60 seconds.
  4. Switch on the voltage with the starter key.
  5. If the fault code it still active, renew the control unit.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 770 in other Scania systems

Compare code 770 in every system →