Scania APS DTC 1306850 Control unit

APS Air Processing System · Scania · 2 variants

Code 1306850 (decimal). Some diagnostic tools show it in hexadecimal as 13F0E2.

In short

Parameter value incorrect.

Variant 1

Applies to: APS2

What does Scania APS fault code 1306850 mean?

Parameter value incorrect.

What causes Scania DTC 1306850?

One parameter or several related parameters have non-consistent values.

How does the system react?

The predefined values are used if the parameter settings are not consistent.

How to fix Scania APS fault code 1306850?

  1. Update the control unit with the latest software.
  2. Clear the fault code.
  3. Turn off the voltage with the starter key.
  4. Wait for 30 seconds.
  5. Switch on the voltage with the starter key.
  6. Spare part program the control unit if the fault code is regenerated.
  7. If the control unit has the latest software and the fault code remains after spare part programming, renew the control unit.

Variant 2

Applies to: APS2

Detection

Parameter value incorrect.

Possible cause

One parameter or several related parameters have non-consistent values.

System reaction

The control unit uses predefined parameters while the fault is active.

How to fix

  1. Clear the fault code.
  2. Turn off the power with the starter key.
  3. Wait for 30 seconds.
  4. Switch on the voltage with the starter key.
  5. If the fault code recurs, renew the control unit.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.