Scania BMU DTC 514 Overloaded software

BMU Battery Management Unit · Scania

Code 514 (decimal). Some diagnostic tools show it in hexadecimal as 0202.

In short

Overload in the control unit processor or memory detected. The system carries out regular load checks of the control unit processor and memory usage. - Memory usage > 85%. - Control unit processor load on 50 Hz > 70%. - Control unit processor load on 100 Hz > 80 %. - Control unit processor load total > 85%.

Applies to: BMU5BMU6 (RES)BMU6 (RESXA)BMU6 (RESXB)BMU6 (RESXC)BMU6 (RESXD)BMU6 (RESXE)BMU6 (RESXF)BMU6 (RESXG)BMU6 (RESXH)BMU6 (RESXI)BMU6 (RESXJ)BMU6 (RESXK)

What does Scania BMU fault code 514 mean?

Overload in the control unit processor or memory detected. The system carries out regular load checks of the control unit processor and memory usage. - Memory usage > 85%. - Control unit processor load on 50 Hz > 70%. - Control unit processor load on 100 Hz > 80 %. - Control unit processor load total > 85%.

What causes Scania DTC 514?

Abnormal external conditions such as faulty communication links. Error in software.

How does the system react?

The system is restored.

How to fix Scania BMU fault code 514?

  1. Clear the fault code if the fault occurs once or twice between two maintenance events.
  2. Check other nodes in the CAN network, both on TMS-SUB-CAN and RES-CAN and the CAN bus cables if the fault recurs regularly.
  3. Renew the BMU E81 if the fault remains after the checks above.
  4. When renewing BMU, run Calibrating propulsion battery information.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 514 in other Scania systems

Compare code 514 in every system →