Scania BMU DTC 790 Fault in direct current converter E84, DCC

BMU Battery Management Unit · Scania · 2 variants

Code 790 (decimal). Some diagnostic tools show it in hexadecimal as 0316.

In short

The direct current converter does not respond correctly to the request from the propulsion battery E83.

Variant 1

Applies to: BMU6 (RES)BMU6 (RESXA)BMU6 (RESXB)BMU6 (RESXC)BMU6 (RESXD)BMU6 (RESXE)BMU6 (RESXF)BMU6 (RESXG)BMU6 (RESXH)BMU6 (RESXI)BMU6 (RESXJ)BMU6 (RESXK)

What does Scania BMU fault code 790 mean?

The direct current converter does not respond correctly to the request from the propulsion battery E83.

What causes Scania DTC 790?

Fault in the software or internal components in the direct current converter.

How does the system react?

Yellow warning indication of an electric drive system fault is displayed. Yellow warning indication that the 24-volt batteries are not charging is displayed.

What are the symptoms?

VOR. The direct current converter will not be activated. The propulsion battery is set to fault status and the 24 V system drains the 24 V batteries.

How to fix Scania BMU fault code 790?

  1. Check and action any other fault codes from the direct current converter.
  2. Clear the fault code.
  3. Turn off the voltage with the starter key.
  4. Wait for 30 seconds.
  5. Switch on the voltage with the starter key.
  6. Read the fault codes again.
  7. If there are still active fault codes, renew direct current converter E84, DCC.

Variant 2

Applies to: BMU5

Detection

The direct current converter does not respond correctly to the request from the propulsion battery E83.

Possible cause

Fault in the software or internal components in the direct current converter.

System reaction

Yellow warning indication that 24 V batteries are not charging is displayed. Yellow warning indication of an electric drive system fault is displayed.

Symptoms

VOR. The direct current converter will not be activated. The propulsion battery is set to fault status and the 24 V system drains the 24 V batteries.

How to fix

  1. Check and action any other fault codes from the direct current converter.
  2. Clear the fault code.
  3. Turn off the voltage with the starter key.
  4. Wait for 30 seconds.
  5. Switch on the voltage with the starter key.
  6. Read the fault codes again.
  7. If there are still active fault codes, renew direct current converter E84, DCC.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 790 in other Scania systems