Scania COO DTC 800 Comfort Shift

COO Coordinator · Scania · 3 variants

Code 800 (decimal). Some diagnostic tools show it in hexadecimal as 0320.

In short

The control unit has detected a fault in the circuit for the Comfort Shift interlock valve. Control unit pin A30 receives information on the signals to the interlock valve and interprets the circuit as shorted to ground.

Variant 1

Applies to: COO8 (COO)COO9 (COO)

What does Scania COO fault code 800 mean?

The control unit has detected a fault in the circuit for the Comfort Shift interlock valve. Control unit pin A30 receives information on the signals to the interlock valve and interprets the circuit as shorted to ground.

What causes Scania DTC 800?

The fault may be due to: - Fault in the cable harness. - Fault in connections. - Fault in interlock valve.

What are the symptoms?

The Comfort Shift interlock function will not function while the fault is active.

How to fix Scania COO fault code 800?

  1. Check: Cable harness and connections between the interlock valve and the control unit.
  2. Comfort Shift interlock valve.
  3. Measure the frequency between signal and ground.

Variant 2: Communication with the SMS control unit

Applies to: COO7

Detection

Communication with the SMS control unit on the yellow CAN bus is interrupted.

Possible cause

Faulty SMS control unit. The SMS control unit has no communication on the CAN bus.

System reaction

Functions dependent on the suspension management system are impaired.

How to fix

  1. Check the fault codes in the suspension management system.
  2. Check the voltage supply and CAN communication to the suspension management system.
  3. Measure the resistance between pins C16 and C7 with the battery disconnected.
  4. Resistance should be around 60 ohms.
  5. (Due to the two termination resistors connected in parallel.)

Variant 3

Applies to: COO8

Detection

The control unit has detected a fault in the circuit for the Comfort Shift interlock valve. Control unit pin A30 receives information on the signals to the interlock valve and interprets the circuit as shorted to ground.

Possible cause

The fault may be due to: - Fault in the cable harness. - Fault in connections. - Fault in interlock valve.

System reaction

The Comfort Shift interlock function will not function while the fault is active.

How to fix

  1. Check: Cable harness and connections between the interlock valve and the control unit.
  2. Comfort Shift interlock valve.
  3. Measure the frequency between signal and earth.