Scania EEC DTC 4352 Reductant circuit

EEC Exhaust Emission Control · Scania

Code 4352 (decimal). Some diagnostic tools show it in hexadecimal as 1100.

In short

The reductant pump needs to run much more slowly than expected to maintain the correct reductant pressure.

Applies to: EEC3

What does Scania EEC fault code 4352 mean?

The reductant pump needs to run much more slowly than expected to maintain the correct reductant pressure.

What causes Scania DTC 4352?

- Blockage in reductant tank return hose. - Blockage in the reductant doser return pipe. - Blockage in the reductant doser injection nozzle. - Reductant pressure sensor in reductant doser indicates values that are too high. - The reductant is frozen. The reductant freezes at -11°C.

How to fix Scania EEC fault code 4352?

  1. Run Wizard for dirt in the SCR system.
  2. Check whether the reductant in the reductant circuit has frozen, look at the temperature in circuit T116.
  3. Check Reductant pick-up unit.
  4. Run the wizard Exhaust gas aftertreatment, troubleshooting the liquid components of the SCR system.
  5. The wizard is used to find blockages in the reductant circuit.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 4352 in other Scania systems

Compare code 4352 in every system →