Scania ACC DTC 22 Aspirator fan

ACC Automatic Climate Control · Scania

Code 22 (decimal). Some diagnostic tools show it in hexadecimal as 0016.

In short

The aspirator fan does not work.

Applies to: ACC1

What does Scania ACC fault code 22 mean?

The aspirator fan does not work.

What causes Scania DTC 22?

Fault on aspirator fan.

How does the system react?

The A/C system switches to manual control (0-10) and to a preset value for the temperature sensor. The A/C system operates at maximum if 0-4 is selected.

How to fix Scania ACC fault code 22?

  1. Check the status of the aspirator fan with SDP3.
  2. Renew the aspirator fan.
  3. Refer to Multi 18-70 for the work description.
  4. As a last resort, renew the ACC control unit.
  5. Calibrate the new control unit by clearing the fault codes.

This information is for guidance only. Always follow the manufacturer workshop manual and safety procedures; if in doubt, contact an authorised workshop.

Code 22 in other Scania systems

Compare code 22 in every system →